1
2
3
4
5
7
L
INSTANT
WATER HEATER
230V
N
E
P
8
4
6
7
7
1
2
3
5
L
230V
N
P
E
6
8
7
7
1
2
3
4
5
L2
L1 400V
230V
N
P
E
1. Multi-pole switch
2. Terminal block
3. Thermostat
5. Switches
6. LED Light
7. Heating elements
8. Pressure switch
8
6
7
4. Microswitch
Table 2
kW loading
220V 230V 240V
3.0 3.3 3.6
3.2 3.5 3.8
5.0 5.5 6.0
5.5 6.0 6.6
7.0 7.7 8.3
7.3 8.0 8.7
8.7 9.5 10.3
Recommended
cable size
Recommended
fuse rating
Model
Heat Setting
New/Lotus - 3.0
New/Lotus - 3.5
New/Lotus - 5.0
New/Lotus - 5.5
New/Lotus - 7.0
New/Lotus - 8.0
New/Lotus - 9.5
1.0;2.0 or 3.0kW
1.5;2.0 or 3.5kW
2.0;3.0 or 5.0kW
2.5;3.0 or 5.5kW
3.0;4.0 or 7.0kW
4.0;4.0 or 8.0kW
4.5;5.0 or 9.5kW
2.5mm2
2.5/4mm2
4/6mm2
4/6mm2
6/10mm2
6/10mm2
10mm2
16amps
20amps
25amps
25-32amps
40amps
40amps
45amps
• Operating water pressure 0.3-7 BAR (5-100 psi) • Water pressure operating power switch
• Standard 1/2"Ø compression inlet connection • Top-left and right cable entry • Bottom-left water entry
Installation Instructions
UNIT DIMENSIONS: HEIGHT 185mm WIDTH 300mm DEPTH 110mm
|
Sylvania SCR1276 User Manual
Sony Ericsson Z750a User Manual
Sony Cell Phone LT30AT User Manual
Samsung ITP 5107 User Manual
Salton MESC10 User Manual
Radio Shack 63 969 User Manual
Pioneer SUPER TUNER 3 D AVIC X920BT User Manual
Panasonic CQ C8200 User Manual
Nokia Cell Phone 2760 User Manual
Graco Nautilus 655 User Manual